Language

labfit products

Labfit Product Range

Below is a quick overview of some of our products. If you don’t find what your are looking we do offer customization services to fully build a system that is unique to your business.

Carbon Sulphur Analysers

Combustion Analyser

Carbon Sulphur Combustion Analyser for Organic Materials

Carbon Sulphur Analysis by combustion for organic materials such as Mineral Ores, Coal, Coking Coal, Soils, Plants, Cements and many more.

Carbon Sulfur Analyser

cs1232-carbon-sulphur

Automated Carbon Sulfur Analyzer with vertical combustion furnace, advanced detection system and 48 position auto-sampler.

Dispensing Systems

Multi Channel Dispensing

Hydra-410-Solution-Dispenser_3

Fast dispensing of multiple solutions has never been easier. The Hydra dispenser up to 4 different solutions at a time.

Water Dispensing

Dispensed_MG_4787_300

Dispense waters and light duty acids or alkalis with the WD3000. The system dispenses to 8 or 10 positions at a time, making sample preparation more efficient.

Automated pH & Conductivity Robots

Single pH & EC

ph-and-conductivity-electrodes-min

Single sample system designed to analyse 1 sample at a time. System has 3 trays holding up to 180 samples.

Dual pH Lime Buffering Capacity for soils

Soil-buffer-ph-robot-electrodes

Perform analysis on 2 samples at the same time. System automatically adds reagent to sample during analysis.

4 pH Electrode

as3000q-multi-ph-soil-testing-robot-electrodes-min

Multi-electrode system analyses 4 samples at once to provide maximum sample throughput.

Single Tray pH & EC

as3020-ph-and-conductivity-analyser-single-tray

With a small form factor, this system system will fit onto any bench and accommodates up to 60 samples.

Automated Acid-Base Titration Instruments

Acid-Base Titrator

TITRATION-PLOT-at-1-INTITAL-PH-DOSE

Perform Acid and Base Titration with our automated solution that accommodates up to 180 samples.

Dual Acid-Base Titrator

1ppm-200ppm-dual-0.05-5g-1

Ask us today about the dual titration system that analyses 2 samples at the same time for higher throughput.

Automated Weighing Instruments

Suspended Solids

Precision Weighing for Automated Suspended Solids analysis

Automated precision autoweigh for suspended solids in environmental samples with 120 sample capacity and 0.01mg resolution.

Total Dissolved Solids

Autoweigh-Total-Dissolved-Solids-Testing

Automated weighing for Total Dissolved Solids (TDS) of drinking water, wastewater, agricultural runoff, sewage, river and stream water.

Organic Matter

weighing-samples-1000x1000

This automated weighing system accommodates up to 80 samples and automatically records all weight losses according to the method.

LOI and TGA

Weigh-station-balances

Easily capture your default weights for TGA or Loss on Ignition systems. All weights are captured and exported to CSV or LIMS.

Robotic LOI

labfit-tga-4000-f4-cooling-rack

Automated 4 stage Loss on Ignition by robot for high volume production samples. Efficient processing of samples in batches of 40, with a 4 stage LOI result typically under 30 minutes. That’s a result every 1.3 seconds.

Weighing Enclosures

Solotec Scientific Balance Enclosures

Place your precision weighing balance into our weighing enclosure to prevent outside influences such as air currents from influencing your weight recordings.

Accessories

pH EC Robot Trolley

AS3000 series trolley

Place your pH Conductivity or Titration system onto this trolley to easily maneuver the robot about your laboratory. Comes with convenient drawer and shelf.

Syringe Pump Module

Labfit-sp48000-dual-syringe-pump

Expand your AS3000 system’s capability by adding a syringe pump to automatically add reagents to your samples.

228l Desiccator Cabinet

Dessicator Caninet 228L

Place your samples, certified refence materials or any thing that needs to be kept free from moisture into this configurable desiccator cabinet.

Desiccator Trolley

150-108-Desiccator-Trolley1000

Easily move your 228l desiccator cabinet about the lab with this lockable trolley that is easy to maneuver.

Read More
cs1232-carbon-sulphur

CS1232 Carbon Sulfur Combustion Analyzer

CS1232 Carbon Sulphur Analyzer for Organic Materials

Carbon Sulphur Combustion Analyser for Organic Materials

Elegant in design, the new CS1232 brings the latest generation in Carbon Sulphur Analysis into view. With significant improvements to the Infrared Detection system, performance gains of 30% and precision/accuracy of 10% are easily achievable. Sample turn-around times are reduced, thus increasing sample throughput. Access to the Anhydrone and furnace temperature controls is concealed behind the push to open door.

Combustion Carbon Sulphur Analyzer

The new CS1232 Carbon Sulphur Analyzer utilises the latest technologies with all new Infrared Detection, 48 Position Autosampler, and improved safety features.

Download the Whitepaper to learn what type of Carbon Sulphur analyzer technology is most suitable for your application.

The Carbon Sulphur Analyser uses advanced infrared technology that improves sample speed without compromising on precision and accuracy.

Solutions & Options in Detail

advanced infrared carbon and sulphur detection for organic materials

IR Detection

The Infrared Detection system is a new optical design making this design far more field serviceable than before which is great for remote locations. The benefit of optics over reflection techniques is such that if the cell chamber becomes dirty, the loss in signal affects the performance of the cell. Not so with an optical infrared design. In fact, because of the new design, the Infrared Detection system is much more sensitive, leading to improved performance, precision & accuracy of results.

Electrical Safety

All power and control of the CS1232 is performed in the furnace power module. Being safety aware, the furnace power module fully encloses access to high voltage/current devices, thus making the system compliant with strict on site safety standards. All external wiring is low voltage (24VDC) and therefore poses no risk to personnel. The module also encloses the over temperature monitoring PID controller for extra added safety.

100-5-GA-3
48 Position Sample Changer

48 Position Sample Changer

The 48 position sample changer is included with all Carbon Sulphur Analyzers as standard. The sample changer and loading mechanism are tightly integrated into the CS1232 significantly improving reliability. The sample loading unit safely inserts the sample crucible into the furnace for combustion and once the analysis of the sample is complete, the loader places the spent sample crucible back into its original position on the sample changer before moving to the next sample.

The CS1232 does not simply drop the hot crucible into a bucket on completion of analysis.

CS1232 Brochure

Download the latest CS1232 product brochure

Download to see for yourself the advanced features and design concept offered by the CS1232.

What Our Customers Are Saying

Frequently Asked Questions

What are some typical applications?

The CS1232 Carbon Sulfur analyzer is suitable for all organic sample types such as; Mineral Ores, Bauxite, Sulfide Ores, Copper Concentrates, Coal, Coking Coal, Soils, Plants, Rubbers, and many more.

Can the CS1232 be used for Oils?

Yes, it can! The CS1232 determines Carbon and Sulfur in oils, diesel, and other combustion liquids by simply using a combustion aid and reducing the furnace temperature to suit.

How expensive are spare parts and consumables?

We pride ourselves in making all our instrumentation very affordable to run. That is why the CS1232 Carbon Sulfur analyzer costs less to run, and in the long term, makes it more affordable than ever.

Is maintenance complicated?

No. Maintenance is much easier on our Carbon Sulfur analyzer because the system is modular allowing for easier access to all components.

Read More
graphite-powder

Measuring Graphite Samples

When measuring graphite samples using a Carbon Sulfur combustion analyser, it is very important that your work area is clean from all possible sources of contamination. A lot of problems associated with analysis of graphite is because of contamination issues. Sources of contamination include, dirty balance pan, dusty (graphite dust) work surfaces, transfer of graphite from hands to crucibles and placement of crucibles onto a unclean surface. Graphite dust is notoriously “sticky” and will easily attach itself to the bottom of crucibles and unknowingly, the operator will then measure a normal sample and get an extremely higher than expected Carbon result.

Measurement of Graphite on the Labfit CS1232 Carbon Sulfur analyser is simplified with special calibration methodologies on the software. Being able to shift the linear curve and then calibrate mean that you can easily analyse very high concentrations of Carbon or Sulfur. To analyse Graphite add your sample to the crucible using a typical weight of 0.25 gram being careful not to contaminate the crucible with extra graphite. Analyse sample as normal. Graphite grease and other graphite products can be analysed on the Labfit CS1232 combustion analyser.

Read More